Analog signal input or external battery voltage measurement. This connection could be used for an external sensor to measure altitude (LIDAR), temperature and so on. This sensor provides a voltage reading.


ADC In

The first part of this menu is to set the conversion from the voltage measurement to the physical variable, according to the offset and sensitivity of the sensor:  Measure = Sensitivity x (Vin – Offset). The result is stored in a variable selected by the user.

The next part allows the creation of an alarm variable that will be triggered when the measured value is lower or greated than a fixed values. For example, in the case of an altimeter, an alarm could be triggered when the measure is lower than 0 or greater than 200 meters. The alarm is stored in a variable selected by the user.