Veronte has two pressure input lines, one for static pressure to determine the absolute pressure and one for pitot in order to determine the dynamic pressure.

Absolute pressure connection on the aircraft is mandatory while pitot port can be obviated in some aircrafts, pitot port absence must be configured on Veronte Pipe software.

Dynamic Pressure

This menu allows the user to configure a dynamic pressure sensor input in Veronte.

Dynamic Pressure

FieldDescription
TypeChoose the dynamic sensor pressure use on the system

  • Disabled: Do not use dynamic pressure sensor for navigation.
  • Custom Settings: Use sensor with custom settings.
  • Autocalibrated Variance: Use sensor with automatic settings.
Square ErrorSensor error
DecimationSensor decimation
Min. PressureMinimum pressure readable by sensor
Pitot OrientationPitot orientation on platform

Dynamic Pressure Sensor Parameters

 

Static Pressure

Configuration of a static pressure sensor used into the Veronte system .


Static Pressure sensor settings panel

FieldDescription
 

Type

Choose the static sensor pressure use on the system

  • Disabled: Do not use static pressure sensor for navigation.
  • Custom Settings: Use sensor with custom settings.
  • Autocalibrated Variance: Use sensor with automatic settings.
Square ErrorSensor error
DecimationSensor decimation
Use Sensor
  • 1: Analogic Sensor. Typical square Error : 100000.0
  • 2: Digital Sensor, better precision. Typical square Error : 1000.0

Static Pressure Sensor Parameters